Alarm Events
The ZSC-1000 incorporates a fully featured alarm handling system. It is fully configurable for alarm sources,
alarm actions and alarm reports. See the Alarm Handling section for more information on how alarms
operate.
Alarm events are the actions that can be configured to occur on the raising of a new alarm.
For each alarm event, in the range 0 to 500
Alarm Action
Record
If enabled a VCR record command will be sent
Default = Off
Switch
If enabled the event camera will be switched to an alarm monitor
Default = On
Primary Action
Action
One of the following actions can be performed on the selected camera (No action, Preset, Walk,
Patrol, Random, Relay On, Relay Off, Relay Pulse, Set Mode)
Default = No action
Note: Relay Actions
If the Primary Action Camera is on a remote site, the relay is also actioned remotely.
Relay Pulse – Relay will switch on and then switch off after 1 second.
The Relay number is entered via the field entry box.
Camera
Camera for the selected action
Default = Event number
Field
The number associated with the action e.g. Preset number
Default = 0
Global
If enabled the action is performed on all cameras at this site
Default = Off
Use Alarm Camera
If enabled the action is carried out on the camera that is the source of the alarm (rather than
configuring a specific camera). This way it is possible to have one event for a range of cameras and
have the event carried out on the camera that is the source of the alarm.
Default = Off