6.3 Freeze Protection Menu
Use Freeze Protection menu to assign freeze protection to your pool and spa equipment. When a piece of equipment
is assigned to freeze protection, it will turn on when the AquaLink PDA detects freezing conditions. The main filter
pump is freeze-protected as a default and cannot be removed from freeze protection.
Activation temperature can be adjusted between 34°F (1°C) and 42°F (6°C). Once activated, freeze protection will
turn off when the air temperature is two (2) degrees higher than the activation point.
CAUTION
Activating the spa during freezing conditions will override freeze protection. This means that if you are
using your spa when freezing conditions exist, freeze protection will
not
circulate water to non-spa
related equipment that you may have freeze protected (for example, the pool cleaner or booster pump)
and thereby increasing the potential for damage to the equipment.
Important Information on Freeze Protection
Freeze protection is intended to protect equipment and plumbing for short periods of freezing only. It
does this by activating the filtration pump and circulating the water to prevent freeze inside equipment
or plumbing. Freeze protection does
not
guarantee that equipment will not be damaged by extended
periods of freezing temperatures or power outages. In these conditions, the pool and spa should be shut
down completely (for example, drained of water and closed for the winter) until warmer weather exists.
6.2 Boost Setup Menu
Use this menu to adjust the number of hours or mode of Boost.
NOTE
The MODE selection is only available if the Power Center Bezel DIP switch S1-3 is turned on (Spillover mode). If it is off,
then only TIME is displayed.
The system will auto-detect the AquaPure
®
chlorine generator.
6.2.1 To set Boost
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight AQUAPURE HRS
and press SELECT. Use the UP/DOWN arrow keys to select TIME.
MAIN MENU
BOOST
HELP
PROGRAM
SET TEMP
SET TIME
SET AQUAPURE
PDA OPTIONS
SYSTEM SETUP
SYSTEM SETUP
LABEL AUX
FREEZE PROTECT
AQUAPURE HRS
AIR TEMP
DEGREES C/F
TEMP CALIBRATE
SOLAR PRIORITY
PUMP LOCKOUT
MORE
BOOST
SET TIME
TIME
24 hrs
Use ARROW KEYS
to set value.
Summary of Contents for AquaLink PDA P4
Page 2: ...Page 2 ENGLISH AquaLink PDA Installation and Operation Manual...
Page 43: ...Page 43 ENGLISH AquaLink PDA Installation and Operation Manual NOTES...
Page 46: ...Page 46 FRAN AIS PDAAquaLink Guide d installation et mode d emploi...
Page 87: ...Page 87 FRAN AIS PDAAquaLink Guide d installation et mode d emploi NOTES...
Page 90: ...P gina 90 ESPA OL PDAAquaLink Manual de instalaci n y operaci n...
Page 131: ...P gina 131 ESPA OL PDAAquaLink Manual de instalaci n y operaci n NOTAS...