10.4 General data
Type
TLC 10K
TLC 15K/17K/20K
Net weight
48 Kg
Dimensions L×W×D
758×500×175 mm
Mounting environment
Indoor and Outdoor
Mounting recommendation
Wall bracket
Operating temperature range
-25… +60
℃
Max. permissible value for relative
humidity ( non-condensing )
100%
Max. operating altitude above mean sea
level
2000 m
Ingress protection
IP65(Electronics)
IP55(Fan)
Climatic category
4K4H
Protection class
I ( in accordance with IEC 62103)
Overvoltage category
DC input: II, AC output: III
Topology
Transformerless
Feed-in phases
3
Cooling concept
Fans
Noise
< 55 dB(A) @ 1m
< 60 dB(A) @ 1m
Display
240×160 Pixels, LCD
Communication interfaces
RS485/USB
Standard warranty
5 years