6
Installation and operating instructions
2 Safety
2.1 Intended use
2.1.1.
.
Eversol converts the direct current from a PV generator into grid-compliant
alternating current.
2.1.2. Eversol is suitable for indoor and outdoor use.
2.1.3. Eversol must only be operated with PV arrays (PV modules and cabling) of
protection class II, in accordance with IEC 61730, application class A.
Do not connect any sources of energy other than PV modules to the Eversol.
2.1.4. PV modules with a high capacitance to earth may only be used if their coupling
capacity does not exceed 1.0
μ
F.
2.1.5. When the PV modules are exposed to light, a DC voltage is supplied to this
equipment.
2.1.6. When designing the PV installation, ensure that the values comply with the
permitted operating range of all components at all times. The free design
program "Zeverplan" (http://www.zeverplan.com) will assist you.
2.2 Safety standards
Eversol complies with the EU Low Voltage Directive 2006/95/EC and the EMC
Directive 2004/108/EC. Evershine also complies with the requirement for safety and
EMC in Australia and New Zealand market.
For more information about certificates in other countries and regions, please visit
website www.zeversolar.com.
Summary of Contents for Eversol-TLC 10K
Page 1: ......