Section 3. Operation
3-2
FRONT PANEL DISPLAY
Table 3.
OPERATION-1
explains the meanings of the common display indications seen on
the front panel of the encoder. In the table, “x” takes the place of any numeric digit.
Table 3. OPERATION-1 Common Display Prompts
Indication
Meaning
-
Ready to accept format leading digit from keypad. More than one hyphen
indicates the unit has only one format programmed.
x-----
Ready to accept pager code number for format x from keypad. The number
of dashes indicates how many capcode digits are expected.
_ _ _ _ _ _
Ready to accept a message from the keypad. This prompt follows the entry
of a display pager capcode.
xxxxxx
Shows last six digits of the pager number or message. If a page has already
been sent, pressing PAGE will repeat the page again (repage function) or
prompt for a new message. When blinking, indicates invalid pager number
not in configured code plan.
buSY
When flashing, indicates that channel is busy and call is being held until
channel is free.
StAC
A pager number has just been accepted into the memory for a keypad
stack. Another pager number may now be input. The new pager number
may also be moved to the memory stack by pressing ENTER; pressing
PAGE will send the pages starting with the most recent entry.
PAGE
Paging information being transmitted.
tALH
(talk) Voice interval is active; speak into desk microphone.
888888
Self-test is running. The self-test must be manually initiated by holding down
the "B" key on power up.
Errx
Error number x detected. Refer to “Self-Test” in Section 6 for error code
explanations.
crt on
Optional serial port is the active communication to the unit. Pressing any
key on the keypad returns the unit to keypad control.
PLACING A PAGE
Format Selection
The encoder shows a single hyphen in the display to prompt for a format selection. One digit,
0-9 or A-D, may be entered to select the format of the following pager number. This leading
digit is not a part of the pager capcode, nor will it be sent as any part of the page, but it is used
to distinguish between formats in a multiple format encoder. If the encoder is programmed for
only a single format configuration, then no format digit entry is required and the encoder
displays a string of hyphens equal to the expected capcode entry length.