Section 5. Programming
5-18
Table 5-14 First Custom Two-Tone Page
Display Keystrokes
Explanation
#####
Plug in the wall transformer. Display shows Z-number & version
number during power up.
2.1
Version 2.1
SEtUP
SEtUP means no formats programmed yet.
ConFIG
C+CLEAR
keys together
Display momentarily shows ConFiG to indicate that it is entering
programming mode.
diGt =0
0 to D ,
ENTER
Select the leading digit. This digit identifies the format that you are
programming.
dELEtE
PAGE, PAGE,
...
PAGE key steps through the format selection menu . Press PAGE key
until c2tonE appears in the display.
c2tonE
ENTER
Select the Custom Two-Tone format.
C
901
Type in 901 for the capcode.
C 901
ENTER
Press ENTER to input the capcode.
A 0.0
10000
Type in 1000.0 Hz for the Tone A frequency. It is not necessary to
input the decimal point.
A1000.0
ENTER
Press ENTER to input the Tone A frequency.
d 0.000
1000
Type in 1.000 seconds for the Tone A duration.
d 1.000
ENTER
Press ENTER to input the Tone A duration.
G 0.000
ENTER
Press ENTER to input 0.000 seconds for gap duration.
b 0.0
15000
Type in 1500.0 Hz for the Tone B frequency. It is not necessary to
input the decimal point.
b1500.0
ENTER
Press ENTER to input the Tone B frequency.
d 0.000
3000
Type in 3.000 seconds for the Tone B duration. It is not necessary to
input the decimal point.
d 3.000
ENTER
Press ENTER to input the Tone B duration
ALrt 0
4
Type in 4 for a “fast siren” Alert function.
ALrt 4
ENTER
Press ENTER to input the Alert function number.
tALH 0
1
Type in 1 to enable talk for this capcode.
tALH 1
ENTER
Press ENTER to input the talk enable/disable selection.
C