Section 5. Programming
5-12
HSC Format
For Hexadecimal Sequential Code (HSC) for PG-50 pagers, select the paging format prompt
“HSC” and then press ENTER. Table 5.
PROGRAMMING-8
shows and explains the
prompts for this format.
Table 5. PROGRAMMING-8 HSC Format Prompts
Major
Prompt
Conditional
Prompt
Explanation
StrP =
Number of digits strapped within the Model 15. A valid response
is from 0 to a maximum of 4 digits.
StP(n)=
If the number of strapped digits programmed is > 0, this prompt
requests the digit desired for the strap number. StP1= would be
the service block and is always the first digit sent, StP2= is the
first pager address digit and would be the next digit sent, and so
on.
rEPt =
Number of times to repeat page. From 0 to 9 repeat pages may
be selected.
tYPE =
Tones/Timing type. 0 = EIA, 1 = CCIR, 2 = ZVEI, 3 = EEA.
SuPS =
Supersave feature enabled, yes or no. 0 = no, 1 = yes.
bAt =
00-60. Time interval in seconds to issue Supersave command.
NOTE
Upon completion of programming, Supersave always defaults to off. Supersave may be
toggled on and off as desired, by typing the leading HSC digit, the character “B” and PAGE
from the keypad. The LED display will momentarily flash the state of Supersave.