60-34
Body
Body
60
Tank Storage Liner
CAUTION:
Always perform the High Voltage
Discharging procedure prior to servicing any
High Voltage component or connection. Proper
procedures must be followed! To protect
electrical components, perform the following
tasks in the order given. Do not deviate from the
repair procedure processes.
NOTICE:
Before carrying out any work on the
electrical system, remove the key from the key
switch.
Tools Required (includes tools required for
parent jobs):
•
T20
•
T25
•
T27
•
T30
•
3/16” standard screwdriver
•
2mm hex wrench
•
6mm hex wrench
•
10mm socket and ratchet
New Fasteners Required:
•
Cable tie (quantity: 2)
Removal
1. Remove high voltage DCDC and CONT fuses.
High Voltage Fuses, page 70.1.
2. Unbolt the negative battery terminal eyelet.
Cover eyelet with insulating material. Use
cable tie to secure negative battery wire to the
positive battery cable. See
CAUTION:
Cover/protect battery terminal
eyelet to reduce the risk of accidentally
contacting the negative battery terminal,
which can inadvertently power up the
12 volt system and damage components.
CAUTION:
Secure battery terminal wire to
reduce the risk of arcing and damaging
electrical components.
3. Remove tank. See
4. Disconnect MBB harness connectors (x2).