Electromagnetic compatibility
000000-2121-813-GA-GB-050416
59
Guidance and manufacturer’s declaration - electromagnetic immunity
The CIRRUS photo is intended for use in the electromagnetic environment specified below. The customer or
the user of the CIRRUS photo should assure that it is used in such an environment.
Immunity test
IEC 60601 test
level
Compliance level
Electromagnetic environment -
guidance
Conducted RF
IEC 61000-4-6
3 V
rms
150 kHz to
80 MHz
3 V
Portable and mobile RF communications
equipment should be used no closer to any
part of the CIRRUS photo, including cables,
than the recommended separation distance
calculated from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
d = 1.2
Radiated RF
IEC 61000-4-3
3 V/m
80 MHz to
2.5 GHz
3 V/m
d = 1.2
80 MHz to 800 MHz
d = 2.3
800 MHz to 2.5 GHz
where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters
a
should be less than the compliance level
b
in
each frequency range.
Interference may occur in the vicinity of
equipment marked with the following
symbol:
Note 1:
At 80 and 800 MHz, the separation distance of the higher frequency range applies.
Note 2:
These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the
CIRRUS photo is used exceeds the applicable RF
compliance Level above, the CIRRUS photo should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as re-orienting or relocating the CIRRUS photo.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m
P
P
P
Summary of Contents for CIRRUS photo 600
Page 1: ...CIRRUS photo CIRRUS photo 600 and CIRRUS photo 800 Documentation set...
Page 4: ......
Page 6: ......
Page 7: ...CIRRUS photo CIRRUS photo 600 and CIRRUS photo 800 User manual...
Page 8: ...000000 2121 813 GA GB 050416...
Page 73: ......
Page 76: ......
Page 77: ...Remote maintenance tool Addendum to the documentation set...
Page 78: ...000000 2121 813 AddGA01 GB 210915...
Page 85: ......
Page 88: ......
Page 104: ...WINDOWS EMBEDDED STANDARD 7 GB 21 06 2012 16...
Page 105: ......