User Manual 3PH HYD5000-HYD20000-ZSS
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1. of 16/03/2021 - Application: GID
28/138
1.
The external BMS (ZST-BMS-SC1000-H)
Figure 15 - BMS
2.
Battery modules (ZST-BAT-2.4KWH-H)
Figure 16 - Battery module to be connected in series
Power connections
The battery modules must be connected in series via the cables shown in figure 4.
The connection cables are supplied with the battery.
Figure 17 - Power connector between battery modules
The connector must be connected from the negative input of the first battery module to the positive
input of the second one. The negative input of the second battery module must then be connected to
the positive input of the third module, continuing the series until the negative input of the second-last
module is connected to the positive input of the last module.