is set to 01 (and in any case, other than 00).
If the value is not 01, go to “Settings” (basic settings for hybrid inverters) and enter the
Modbus Address menu where the 01 value can be set.
-
Check that the Wi-Fi adapter is correctly and securely connected to the inverter, making
sure to tighten the two cross-head screws provided.
-
Check that the Wi-Fi symbol is present in the top right-hand corner of the inverter's display
(steady or flashing).
Figure 105 – Icons on the display of LITE single-phase inverters (left) and three-phase or hybrid inverters
(right)
-
Restart the adapter:
•
Press the reset button for 5 seconds and release
•
After a few seconds, the LEDs will turn off and will start to flash quickly
•
The adapter will now be reset without having lost the configuration with the router
2) Irregular communication with remote server
-
NET (left LED ): off
-
COM (central LED): on
-
READY (right LED): flashing on
Figure 106 - Irregular communication status between Wi-Fi and remote server
-
Check that the configuration procedure has been carried out correctly and that the
correct network password has been entered.