User Manual 3PH HYD5000-HYD20000-ZSS
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1. of 16/03/2021 - Application: GID
135/138
11.3.2.
Verification
After installing the adapter, within the next 3 minutes check the status of the LEDs on the device to
ensure that the device is configured correctly.
Status of LEDs present on the adapter
1)
Initial status:
-
NET (left LED ): off
-
COM (central LED): flashing on
-
SER (right LED): flashing on
Figure 119 - Initial status of LEDs
2)
Registration:
-
NET (left LED): flashes rapidly for about 50 seconds; the registration process takes
about 30 seconds
-
COM (central LED): flashes rapidly 3 times after 50 seconds
3)
Final status (approx. 150 seconds after the inverter has started):
-
NET (left LED): flashing on (off and on at equal intervals)
-
COM (central LED): steady on
-
SER (right LED): steady on