Rev. 3/2001 89
Avoid getting Teflon Tape
within the air path!
Air Fitting
Teflon Tape
Tape should be kept away
from end of threaded
fitting.
One thread
on end with
no tape!
Teflon Tape
Chromira Air-Solenoid Installation
Introduction
The Chromira Air-Solenoid allows the Chromira Printer to turn off its
compressed air supply while not making prints. This will reduce the wear on
your air-compressor and prolong its life.
This document describes the procedure for the installation of the Air-Solenoid
and its related components.
Warnings
Before beginning this installation, please observe
the following:
Power should be turned off before doing any
work on the Chromira.
To avoid possible damage to the Motion Control
Electronics, do not use your existing Motion
Control Power Supply once the Air-Solenoid is
installed. The Air-Solenoid installation kit will have
a new Motion Control Power Supply included.
When making air plumbing connections, avoid getting Teflon tape near the
openings of, or inside, the air fittings. If Teflon tape gets inside the air duct, it will
cause serious damage to the air rail.
What You Need
Summary of Contents for CHROMIRA
Page 1: ...Rev 3 2005 ZBE CHROMIRA PRINTER User s Manual...
Page 26: ...Chromira 26 Diagram A...
Page 55: ...Rev 3 2001 55...
Page 57: ...Rev 3 2001 57 information...
Page 59: ...Rev 3 2001 59 TECHNICAL DOCUMENTS Simple Windows NT Networking Setup...
Page 70: ...Chromira 70...