Rev. 3/2001 83
Once strip is read, be sure it has read 17 regions on the Densitometer. If it does
not, click the cancel button in the Chromira Balance program and try it again.
X-Rite 414 Configuration Menu Settings
To set the Com Port Mode for use with ZBE Chromira Balance, press Function
and Color. Press Function again to select No for calibrate. Then, press Zero to
choose Yes for modes.
Press the Function key twice to reach the I/O-RS232 menu, then press Zero to
select it. Press the Zero key to change settings for each field, and the Function
key to change menu fields.
SEND:
AUTO
BAUD:
Don't care
PRINT HDR:
ON/OFF
COMP:
ON/OFF
Press the Function key two more times to return to normal operation.
To set the function, press the Function key until the screen displays DEN, then wait
for the normal screen to reappear.