ADVField Operation Manual (September 1, 2001)
Table 16. DB9 Connector Pin-outs for Serial Communications
Pin #
Signal
Pin #
Signal
Pin #
Signal
1
Rx-
4 Not
used 7 Not
used
2
Data Out / Tx+
5
Ground
8
Not used
3
Data In / Tx-
6
Not used
9
Rx+
The last connector on the splash-proof housing, a DB15, gives access to auxiliary input / output
signals. Table 17 lists the pin out for the DB15 connector.
Table 17. DB15 Connector Pin-outs for Auxiliary I/O Signals
Pin #
Signal
Pin #
Signal
Pin #
Signal
1 Vx 6
SyncIn
11
Ground
2 Vy 7
SyncOut
12
Ground
3 Vz 8 +5
V
13
Ground
4 Amp 9 Ground
14
Ground
5 Ground 10 Ground 15 Ground
4.3.2. ADVField Underwater Canister
There are two connectors on the ADVField underwater canister: one to the probe and the other
for power, serial communications, and auxiliary input / output functions. Underwater mateable
connectors are used for both (some older ADVs used different connectors; contact SonTek if you
have any questions about the connectors used on your system). The high-frequency cable from
the ADVField underwater canister to the probe is a custom-shielded, highly noise-sensitive cable.
Contact SonTek before making any modifications to this cable or connector.
SonTek uses underwater connectors made by Impulse Enterprises. Contact information for Im-
pulse (if ordering items directly) is:
Impulse
Enterprises
8254 Ronson Road, San Diego, CA 92111
Phone (619) 565-7050, Fax (619) 565-1649
Two different types of connectors are used for power and communications.
•
For most autonomous ADVField systems (with internal recorder and battery power):
o
The external power and communication connector is a female, 8-pin, underwater mate-
able connector (although some use the female, 16-pin connector described below).
o
The bulkhead connector used is an Impulse BH-8-FS.
o
The mating connector on the cable is an Impulse IL-8-MP (with locking sleeve).
o
Table 18 gives the pin-out for this connector.
Table 18. Impulse IL-8-MP Connector Pin-outs
Pin
# Signal Pin
# Signal Pin
# Signal
1 Vpower 4 Drain 7 Rx-
2
Data Out / Tx+
5
SyncIn
8
Ground
3
Data In / Tx-
6
Rx+
Summary of Contents for SonTek ADVField
Page 2: ......
Page 8: ...SonTek YSI iv ADVField Hydra Operation Manual September 1 2001 NOTES ...
Page 12: ......
Page 32: ...SonTek YSI 20 ADVField Operation Manual September 1 2001 ...
Page 102: ...SonTek YSI 90 ADVField Operation Manual September 1 2001 ...
Page 104: ...SonTek YSI 92 ADVField Operation Manual September 1 2001 ...
Page 118: ...SonTek YSI 106 ADVField Operation Manual September 1 2001 ...
Page 122: ...SonTek YSI 110 ADVField Operation Manual September 1 2001 ...
Page 126: ...SonTek YSI 2 ADVField Operation Manual September 1 2001 ...
Page 132: ...SonTek YSI vi ADVField Software Manual September 1 2001 NOTES ...
Page 136: ...SonTek YSI ADVField Software Manual September 1 2001 4 ...
Page 152: ...SonTek YSI ADVField Software Manual September 1 2001 20 ...
Page 160: ...SonTek YSI ADVField Software Manual September 1 2001 28 ...
Page 162: ...SonTek YSI ADVField Software Manual September 1 2001 30 ...
Page 164: ...SonTek YSI ADVField Software Manual September 1 2001 32 ...
Page 168: ...SonTek YSI ADVField Software Manual September 1 2001 36 ...
Page 174: ...SonTek YSI ADVField Software Manual September 1 2001 42 ...
Page 182: ...SonTek YSI ADVField Software Manual September 1 2001 50 ...
Page 184: ...SonTek YSI ADVField Software Manual September 1 2001 52 Figure 15 ViewHydra Screen Shot ...
Page 196: ...SonTek YSI ADVField Software Manual September 1 2001 64 ...
Page 198: ...SonTek YSI ADVField Software Manual September 1 2001 66 ...
Page 202: ......
Page 206: ......
Page 220: ...SonTek YSI Acoustic Doppler Velocimeter Principles of Operation September 1 2001 14 ...