Message
Meaning
EVU STOP
Indicates that the additional function EVU is active. This means that
the heat pump compressor and addition are off as long as EVU is
active.
NO DEMAND
HEAT
Indicates that there is no heating production demand.
HIGHPRESS
ERROR
Alarm that indicates that the high pressure switch has deployed.
LOWPRESS
ERROR
Alarm that indicates that the low pressure switch has deployed.
MOTOR P
ERROR
Alarm that indicates that the motor protection has deployed.
BRINEFLOW
LOW
Appears if the accessory flow switch is installed. Indicates that the
flow in the brine system is low.
SENSOR
Alarm that indicates a faulty sensor.
HEATPUMP
START
Indicates that the compressor will start within 30 seconds. The brine
pump has started.
H
ADD.HEAT
Indicates that heat production is active with both compressor and
auxiliary heater.
START – -MIN
Indicates that there is a heating production demand and will start in
the specified number of minutes.
ADD. HEAT
Indicates that there is an auxiliary heater demand.
Text specific to Geysir Air
Appears with applicable heat pump operating status text.
Message
Meaning
DEFROST
Indicates the temperature for defrost.