ENGLISH
28
3 .2 .5
Sub-menu TEMPERATURE
I
n the TEMPERATURE menu you are able to view the
various temperatures that the installation has had. All
temperatures are stored 100 minutes (factory setting)
back in time so that they can also be displayed in the
form of graphs.
Menu text
Description
Adjusted by:
OUTDOOR
Shows the actual outdoor temperature.
ROOM
If ROOM shows 20°C the heat curve is unaffec-
ted. If ROOM shows higher or lower, this indi-
cates that the heat curve has been adjusted up
or down to change the indoor temperature.
By the customer,
if necessary.
SUPPLY PIPE
Shows the actual supply temperature.
(The desired value is shown between brac-
kets)
Read the ”Regulation information” section
for more information.
(In operating mode ADD.HEAT the stop
temperature for hot water production is
shown in brackets, increased by 5°.)
Not adjustable
(The computer
calculates the
temperature requi-
red to maintain
the indoor tempe-
rature.)
RETURN PIPE
Shows the read return temperature. (The
highest permitted temperature is shown
between brackets.)
Authorized ins-
taller.
Adjusted for each
installation.
HOT WATER
Shows the actual hot water temperature.
Not adjustable.
INTEGRAL
Heat production is controlled by a calculated
demand that is automatically calculated when
the installation is in operation. The value for
the integral displays the heating system’s
actual energy balance. Read the ”Regulation
information” section for more information.
Not adjustable.
BRINE OUT
The temperature of the brine circuit
going out from the heat pump.
Not adjustable.
BRINE IN
The temperature of the brine from the heat
source.
Not adjustable.
POOL
(Only displayed if an
Expansion card is installed)
Shows the actual pool temperature.
The set pool temperature is shown in brackets.
Not adjustable.
SHUNT GROUP
(Only displayed if an
Expansion card is installed)
Shows the actual supply temperature. The cal-
culated supply temperature to the shunt group
is within brackets.
Not adjustable.
COOLING
(Only displayed if an
Expansion card is installed)
Shows the actual supply temperature. The set
point value is shown in brackets.
Not adjustable.
CURRENT
(Only displayed if an
Expansion card is installed)
Shows the actual current consumption. The set
value for MAX CURRENT is shown between
brackets.
Not adjustable.
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
0°C
20°C
38(40)°C
34(48)°C
52°C
-660
-7°C
TEMPERATURE