![background image](http://html1.mh-extra.com/html/york/geysir/geysir_user-manual_3958686035.webp)
ENGLISH
35
EN
3. Open the menu by pressing the right button once.
4. The cursor is at the OUTDOOR value.
5. Press the up or down button to move the cursor to the desired value.
6. Open your selection by pressing the right button once. A graph appears in the display.
7. Move the cursor along the time axis using the up (plus) or down (minus) buttons. An
exact value at the relevant time is shown at the top of the display.
8. Press the left button three times to exit the menu.
5 .8
Calculating energy consumption, Geysir, Geysir with
Passive cooling
The energy consumption calculation is difficult to specify exactly, but the average output for
a normal house with normal hot water consumption in the following tables gives a relatively
accurate result for each heat pump and heating system. Remember that the operating time
for the heat pump installation must exceed one year before the specified values in the table
are valid.
The energy consumption for legion operation is included in the hours for ADD.HEAT 1.
The indicated outputs include circulation pumps.
Geysir
6
8
10
12
16
Under floor
heating
1.59 kW
2.00 kW
2,55 kW
2.90 kW
4.31 kW
Radiators
1.88 kW
2.36 kW
3.03 kW
3.43 kW
5.11 kW
Geysir with
Passive cooling
6
8
10
Under floor
heating
1.59 kW
2.00 kW
2.55 kW
Radiators
1.88 kW
2.36 kW
3.03 kW
To calculate the energy consumption:
1. Press either the right or left button once to open the INFORMATION main menu. The
cursor is in the OPERATION menu option.
2. Press the down button to move the cursor to the OPERAT.TIME menu option.
3. Open the menu by pressing the right button once.
4. Note how many hours the following values have: HEATPUMP, ADD.HEAT 1, and
ADD.HEAT 2.
5. In the tables above find the value for the average output that corresponds to your heat
pump and heating system, and multiply it by the number of HEAT PUMP hours. Note the
result.
6. Multiply the number of ADD.HEAT 1 hours by 3. Note the result.
7. Multiply the number of ADD.HEAT 2 hours by 6. Note the result.
8. Add up the multiplied values to obtain the total energy consumption.