3 .2 .6
Sub menu OPERAT . TIME,
Geysir, Geysir with Passive cooling
In the OPERAT.TIME menu you are able to view the opera-
ting time of the installation. Operating times cannot be reset
but are accumulated during the service life of the heat pump.
The control computer calculates the operating time in
minutes but only complete hours are shown in the display.
Menu text
Description
Adjusted by:
HEATPUMP
Shows the total time in hours that the heat
pump has been in operation since installa-
tion. The number of operating hours inclu-
des the time for both heat production and
hot water production.
Not adjustable.
ADD. HEAT 1
Shows the total time in hours that the auxi-
liary heater (3 kW) has been in operation
since installation.
Not adjustable.
ADD. HEAT 2
Shows the total time in hours that the auxi-
liary heater (6 kW) has been in operation
since installation.
Not adjustable.
HOT WATER
Shows a part of the time that is included
in the HEAT PUMP value. The number of
hours that hot water production has been in
operation since installation are shown here.
Not adjustable.
COOLING
(Only displayed if an
Expansion card is installed)
Operating time passive cooling.
Not adjustable.
ACT COOLING
(Only displayed if an
Expansion card is installed)
Operating time passive cooling.
Not adjustable.
The auxiliary heater is made up of an electric heating element on the supply pipe that has
two outputs, ADD.HEAT 1 and ADD.HEAT 2, and can be controlled in three steps. For three
phase 400V heat pumps the outputs are in the different steps:
l
Step 1 = ADD.HEAT 1 = 3 kW
l
Step 2 = ADD.HEAT 2 = 6 kW
l
Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 9 kW
For single phase 230V heat pumps the outputs are in the different steps:
l
Step 1 = ADD.HEAT 1 = 1.5 kW
l
Step 2 = ADD.HEAT 2 = 3 kW
l
Step 3 = ADD.HEAT 1 + ADD.HEAT 2 = 4.5 kW
HEATPUMP
ADD. HEAT 1
ADD. HEAT 2
HOT WATER
0H
0H
0H
0H
OPERAT.TIME