3 .2 .4
Sub-menu HEATCURVE 2
The menu only applies if the expansion card is installed
and only appears if shunt group sensor is connected
and activated. Used to change settings for heat curve 2.
Menu text
Description
Adjusted by:
CURVE 2
Calculated shunt group temperature at 0°C
outdoor temperature. Shown as a graph
that also shows MIN and MAX values.
By the customer,
if necessary.
MIN
Minimum permitted shunt group temperaure,
if the temperature for heat stop has not been
reached.
Authorized installer.
Adjusted for each
installation.
MAX
Maximum permitted shunt group temperature. Authorized installer.
Adjusted for each
installation.
CURVE 2
MIN
MAX
40
°
C
10
°
C
55
°
C
HEATCURVE 2