11-12
11.7 Commands (before the IEEE 488.2-1987 Standard)
For a detailed description of each command, refer to appendix 1.1.
Command
Description
Wiring system
WRm (WiRing)
sets wiring system
Voltage range
RVm (Range Voltage)
sets voltage range
AVm(Auto Voltage range)
sets voltage auto range
Current range
RAm(Range current(A))
sets current range
AAm(Auto current(A) range)
sets current auto range
SAm(Sensor Ampere)
sets external sensor
Display range
DR(Display Range)
sets external sensor
Measurement mode
MNm(MeaN)
sets external sensor
Filter
FLm(FiLter)
sets filter ON/OFF
Hold
HDm(sampling HolD)
holds display and output data
Trigger
E or ST or <GET>
trigger
Display
DAm(Display A function)
selects function to be displayed on display A
DBm(Display B function)
selects function to be displayed on display B
DCm(Display C function)
selects function to be displayed on display C
EAm(Element display A)
selects element to be displayed on display A
EBm(Element display B)
selects element to be displayed on display B
ECm(Element display C)
selects element to be displayed on display C
Scaling
SCm(SCaling)
sets scaling ON/OFF
KVm(K*Amplre)
sets the scaling value
KAm(K*Wattage)
KWm(K*Voltage)
Averaging
AGm(AveraGing)
sets averaging ON/OFF
ATm(Averaging Type)
selects exponential averaging or moving averaging
ACm(Averaging Coefficient)
sets attenuation constant or averaging number
MATH
MTm(MaThematics)
Sets computing equation
Integration
IS(Integrate Start )
starts integration
IP(Integrate stoP)
stops integration
IR(Integrate Reset)
resets integration
ICm(Integrate Continuous)
sets integration mode
TMm1,m2(integrate TiMer)
sets integration preset time
Data storage
SO(Store On)
starts storage
SRm1,m2,m3(Store inteRval)
sets storage interval
Data recalling
ROm(Recall On)
starts recalling
RRm1,m2,m3(recall inteRval)
sets recalling interval
Set-up parameters
SLm(panel Setting Load)
recalling set-up parameters
SSm(panel Setting Save)
storing set-up parameters
RC(Reset Command)
initialize set-up parameters
Communication
CMm(Communication coMmand)
sets command group to be used
commands
OD(Output Data)
requests output of measured data
OFm1,m2,m3(Output Function)
sets output items
OFDm(Output Function Default)
sets default output items
OS(Output panal Setting)
requests output of setting parameters
OE(Output Error code)
requests output of error code
Hm(Header)
sets output data header
DLm(DeLimiter)
sets output data delimiter
IMm(Interrupt Mask)
sets status byte interrupt mask
/HAM (option)
HAm(Harmonics Analize)
sets harmonic analysis ON/OFF
HEm(Harmonics Eiement)
sets harmonics element
OR(harmonics ORder)
sets harmonics order
OHm1,m2(Output Harmonics function) sets communication or output block
PSm(Pll Source )
sets PLL source
DFm(Distortion Formula)
sets distortion formula
/DA (option)
OAm1,m2,m3(Output Analog)
sets output items yourself
OADm(Output Analog Default)
sets default output items
RTm1,m2,(integrate Rated Time)
sets integration time
/CMP (option)
YOm(relaY On)
sets comparator function ON/OFF
YMm(relaY Mode)
sets comparator mode
DYm(Display relaY)
sets display relay ON/OFF for comparator
YCm(relaY Channel)
sets the relay channel
OYm1,m2,m3,m4,m5
sets the output relay function for normal measurement
(Output relaY function)
OYHm1,m2,m3,m4,m5,m6
sets the output relay function for harmonic analysis
(Output relaY Harmonic function)
Note
• If commands relating to options are used on instruments which do not have the options installed, "Error
11" is displayed. Also, there are no responses to inquiries.
• "MATH" is available on WT110/WT130 with ROM version 2.01 or later.