22-9
IM PX8000-02EN
History Data Range of Waveforms to Be Saved (History)
One: The one waveform that is specified with Selected Record on the HISTORY menu will be
saved. To save an averaged history waveform, set the history feature’s display mode to
Average Record, and then select One.
All: All history waveforms within the range bounded by Start Record and End Record on the
HISTORY menu will be saved. If you search for history waveforms, and then select All, only
the detected waveforms will be saved. All waveforms (All) cannot be used to save waveforms
when the data format is WDF Binary.
Selecting the Waveforms to Save (Select Save Trace)
You can select All ON, U1 to U4, I1 to I4, P1 to P4, AUX3 to AUX8, and Math1 to Math8 waveforms.
The displayed waveforms that you select are saved. The setup data for the saved waveforms are
also saved.
• Waveforms that are not displayed will not be saved even if you select them.
• Math1 to Math8 are available when the data type (Data Type) is ASCII or Float.
• If the computation mode on the MATH menu is set to OFF, Math1 to Math8 cannot be
selected.
• Any computation channels (Math1 to Math8) whose operation is set to OFF on the MATH
menu cannot be selected.
• Any computation channels (Math1 to Math8) whose display is set to OFF on the MATH menu
will not be displayed. Therefore, they will not be saved.
• If the data type is set to Binary, source waveforms for waveform computation on the MATH menu
are saved even if they are not displayed. Therefore, even though Math1 to Math8 are cannot be
specified to be saved when the data type is set to Binary, when binary data is loaded, Math1 to
Math8 may appear depending on the setup data of the MATH menu.
• If the data type is set to ASCII or Float and you select All for saving history waveforms, Math1 to
Math8 will not be saved. If you want to save Math1 to Math8, set History to One.
Starting to Save (Execute Save)
Press the
Execute Save
soft key to save the waveform data file to the specified folder.
22.3 Saving Waveform Data