73
Conversion Technique for Rate ................................................................................... 1/period
Conversion Time for Rate .......................................... Gate time + 30 ms + 0-2 signal periods
Time Before Zero Output for Rate ................................................ 0 to 199.99 sec (selectable)
Zero Wait Time for Rate ............................................................... 0 to 199.99 sec (selectable)
Output & Display Update Rate ......................................................... Same as conversion rate
Time Base Accuracy for Rate ................................................................. Calibrated to ±2 ppm
POWER REQUIREMENTS
Input Voltage Rating (standard) ...................................................... 85-264 Vac or 90-300 Vdc
Input Voltage Rating (low voltage option) ........................................... 12-32 Vac or 10-48 Vdc
Power Line Frequency ................................................................................. DC and 47-63 Hz
Power Consumption, Max ........................................................................................... 5 Watts
EXCITATION OUTPUTS
Voltage & Current Levels (jumper selectable) .................................. 5V dc ±5%, 100 mA max
.......................................................................................................
10V dc ±5%, 120 mA max
........................................................................................................
24V dc ± 5%, 50 mA max
Excitation Output Ripple ..................................................................................... 100 mVp max
Isolation from Power and Outputs .............................................................................. 250 Vac
Insulation Dielectric Strength to Power & Outputs ...... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min
Isolation to Signal Common ......................................................................................... 50V dc
DUAL OR QUAD RELAY OPTIONS
Power to Relay Option ................................................................................ Powered by meter
Setpoint Setup ....................................................... Via front panel pushbuttons or RS232/485
Update Rate .................................................................................56/s at 60 Hz, 47/s at 50 Hz
Response to Input Signal (min) ................................................................. Display update rate
Input Signal (selectable) ........................................................ Filtered or unfiltered input signal
Actuation Modes (selectable) ...... Above or below setpoint, latching or non-latching, disabled
Output Time Delay (selectable) .................................................................... 1 to 128 readings
Front Panel Enable / Lockout Modes (selectable) ................ 1) Display and change setpoints
...................................................................................
2) Display but do not change setpoints
..................................................................................
3) Neither display nor change setpoints
Alarm Status Indication .......................................................................... 2 or 4 red LED lamps
Status Indication Setup (selectable) .......................................... Lit when output is ON or OFF
Form C, SPDT Relay Output:
AC Rating ......................................................................................................... 8A @ 240 Vac
DC Rating ........................................................................................................... 8A @ 24 Vdc
Isolation rating between signal common and contacts ............................................... 250 Vac
Insulation dielectric strength between signal common and contacts ........................................
................................................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min
Form A, SPST Solid State Relay Output:
AC Rating .................................................................................................. 130 mA @ 140 Vac
DC Rating .................................................................................................. 130 mA @ 180 Vdc
Isolation rating between signal common and contacts ............................................... 250V ac
Insulation dielectric strength between signal common and contacts ........................................
................................................................................... 3.5 kV ac for 5 sec, 2.3 kV ac for 1 min
Summary of Contents for 800 plus
Page 63: ...63 SERIAL CONNECTION EXAMPLES ...