29
Press
Menu
Press Digit Select
Key
Press Value Select
Key
Coordinates of 2 points scaling method if selected under
SEtuP
.
Lo
_
In1
.
Low signal
input 1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Move decimal point location
when flashing.
Lo
_
rd1
Reading at
Lo In1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Decimal point is fixed by
dEC.Pt1
.
.
Hi
_
In1
.
High signal
input 1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Move decimal point location
when flashing.
.
Hi
_
rd1
.
Reading at
Hi In1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Decimal point is fixed by
dEC.Pt1
.
.
Lo
_
In2
.
Low signal
input 2.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Move decimal point location
when flashing.
Lo
_
rd2
Reading at
Lo In2.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Decimal point is fixed by
dEC.Pt1
.
.
Hi
_
In2
.
High signal
input 1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Move decimal point location
when flashing.
.
Hi
_
rd2
.
Reading at
Hi In1.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Decimal point is fixed by
dEC.Pt1
.
Preset function. Displayed for Total modes
A-b_Ud
.
or
A_bU/d
PrESEt
Preset*
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits.
dEC.Pt1
is used. When the
meter counts up and reaches the Preset, it reverts to
Offset1. When the meter counts down and reaches
Offset1, it reverts to Preset. Set to 0 for no Preset.
Special curve offset for square root or custom curve linearization if selected under
ConFiG
.
rd0
_
In
.
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Decimal point is fixed by
dEC.Pt1
.
Summary of Contents for 800 plus
Page 63: ...63 SERIAL CONNECTION EXAMPLES ...