36
Press
Menu
Press Digit
Select Key
Press Value Select
Key
bAtCH
Batch setup
_
0
0000
&
_0
0
000
0
Not used with VF Batch. Set to 0.
_00
0
00
Batch triggering
0
Use gate time* as delay between batches.
1
Use External Input B to start each new batch.
_000
0
0
Definition of Item #2
0
Make Item #2 the Grand Total of all batches.
1
Make Item #2 the Total Number of batches.
_0000
0
Action after Meter Reset
0
Display “rEAdy.” R
ESET
key starts batching.
1
Start batching upon Meter Reset.
FiLtEr
Filtering
_
0
0000
Signal filtering
0
Adaptive moving average filter. Restarts filter for
high actual changes in signal.
1
Conventional moving average filter without reset.
_0
0
000
Peak & Valley filtering
0
Peak* or Valley* value from unfiltered signal.
1
Peak* or Valley* value from filtered signal.
_00
0
00
Display filtering
0
Display value of unfiltered signal.
1
Display value of filtered signal.
_000
0
0
Adaptive filter setup
0
Set adaptive filter for normal noise.
1
Set adaptive filter for presence of high transients.
_0000
0
Filter time constant
0
No filter
1
0.1 sec
2
0.2 sec
3
0.4 sec
4
0.8 sec
5
1.6 sec
6
3.2 sec
7
6.4 sec
dEC.Pt1
Decimal pt1
1
.
11111
Decimal point flashes.
1
.
11111
11
.
1111
111
.
111
1111
.
11
11111
.
1
111111
.
Press to shift the decimal point.
dEC.Pt22
Decimal pt2
2
.
22222
Decimal point flashes.
2
.
22222
22
.
2222
222
.
222
2222
.
22
22222
.
2
222222
.
Press to shift the decimal point.
Scale and Offset scaling method if selected under
SEtuP
SCALE1
Scale
Factor 1
0
.00000 0.
0
0000 0.0
0
000
0.00
0
00 0.000
0
0 0.0000
0
Select the digit to flash
for the Scale Value, then
press one more time
for the Scale Multiplier.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. This will set the Scale Value*
from -9.99999 to 9.99999 with a fixed decimal point.
Then press to select a value from
0.00001
to
100000
in decade steps for the Scale Multiplier.
Scale Factor = Scale Value x Scale Multiplier.
OFFSt1
.
Offset 1
0
00000 0
0
0000 00
0
000
000
0
00 0000
0
0 00000
0
Select digit to flash.
Select
-9
thru
9
for flashing first digit and
0
thru
9
for
other flashing digits. Use
dEC.Pt1
to set the decimal
point.
SCALE2
Scale Factor 2.
Make the same Scale Factor 1.
OFFSt2
.
Offset 2.
Make the same as for Offset 1.
Summary of Contents for 800 plus