![YASKAWA Z1000U Series Programming Manual Download Page 269](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538269.webp)
Table A.26 200 V, 1150 r/min Type Yaskawa SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM
Motors)
−
1410
1412
1413
1414
1432
1433
1435
1436
Voltage Class
V
200
200
200
200
400
400
400
400
Rated Power
kW
22.00
30.00
37.00
45.00
0.4
0.75
1.5
2.2
Rated Speed
r/min
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor Rated Power (for PM Motors)
kW
22
30
37
45
0.4
0.75
1.5
2.2
E5-03
Motor Rated Current (for PM
Motors)
A
74.4
104.2
129.6
154.2
0.94
1.51
3.00
4.43
E5-04
Number of Motor Poles (for PM
Motors)
−
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for
PM Motors)
Ω
0.048
0.035
0.023
0.016
19.320
10.800
4.456
2.044
E5-06
Motor d-Axis Inductance (Ld) (for
PM Motors)
mH
2.38
2.04
1.53
1.16
194.70
129.20
76.88
48.60
E5-07
Motor q-Axis Inductance (Lq) (for
PM Motors)
mH
3.15
2.86
2.27
1.54
252.84
160.90
97.52
61.40
E5-09
Motor Induction Voltage Constant 1
(Ke) (for PM Motors)
mVs
/rad
410.9
436.1
428.8
433.3
640.9
654.1
728.8
688.9
E5-24
Motor Induction Voltage Constant 2
(Ke) (for PM Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Voltage
V
190.0
190.0
190.0
190.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
Table A.27 400 V, 1150 r/min Type Yaskawa SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM
Motors)
−
1438
143A
143B
143D
143E
143F
1440
1442
Voltage Class
V
400
400
400
400
400
400
400
400
Rated Power
kW
3.7
5.5
7.5
11
15
18
22
30
Rated Speed
r/min
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor Rated Power (for PM
Motors)
kW
3.7
5.5
7.5
11.0
15
18.50
22.00
30.00
E5-03
Motor Rated Current (for PM
Motors)
A
7.08
10.10
13.33
19.9
27.8
31.8
37.2
52.1
E5-04
Number of Motor Poles (for
PM Motors)
−
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1)
(for PM Motors)
Ω
1.483
1.215
0.660
0.443
0.331
0.264
0.192
0.140
E5-06
Motor d-Axis Inductance (Ld)
(for PM Motors)
mH
37.58
44.54
26.36
19.10
15.09
13.32
9.52
8.16
E5-07
Motor q-Axis Inductance (Lq)
(for PM Motors)
mH
47.65
56.26
34.20
24.67
18.56
18.00
12.60
11.40
E5-09
Motor Induction Voltage
Constant 1 (Ke) (for PM
Motors)
mVs
/rad
702.0
861.5
783.0
762.2
749.6
842.7
821.8
872.3
E5-24
Motor Induction Voltage
Constant 2 (Ke) (for PM
Motors)
mV/
(r/min)
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Voltage
V
380.0
380.0
380.0
380.0
380.0
380.0
380.0
380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
269
A
Parameter List