![YASKAWA Z1000U Series Programming Manual Download Page 263](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538263.webp)
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
The following tables show parameters and default settings that change with the motor code selection E5-01 when Open Loop
Vector for PM motors is used.
u
Yaskawa SMRA Series SPM Motor
Table A.14 200 V, 1800 r/min Type Yaskawa SMRA Series SPM Motor Settings
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
0002
0003
0005
0006
0008
Voltage Class
V
200
200
200
200
200
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
Rated Speed
r/min
1800
1800
1800
1800
1800
E5-02
Motor Rated Power (for PM Motors)
kW
0.4
0.75
1.5
2.2
3.7
E5-03
Motor Rated Current (for PM Motors)
A
2.1
4.0
6.9
10.8
17.4
E5-04
Number of Motor Poles (for PM Motors)
–
8
8
8
8
8
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
2.47
1.02
0.679
0.291
0.169
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
12.7
4.8
3.9
3.6
2.5
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
12.7
4.8
3.9
3.6
2.5
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs
/rad
0
0
0
0
0
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/
(r/min)
62.0
64.1
73.4
69.6
72.2
E1-04
Maximum Output Frequency
Hz
120
120
120
120
120
E1-05
Maximum Voltage
V
200.0
200.0
200.0
200.0
200.0
E1-06
Base Frequency
Hz
120
120
120
120
120
E1-09
Minimum Output Frequency
Hz
6
6
6
6
6
Table A.15 200 V, 3600 r/min Type Yaskawa SMRA Series SPM Motor Settings
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
0103
0105
0106
0108
Voltage Class
V
200
200
200
200
Rated Power
kW
0.75
1.5
2.2
3.7
Rated Speed
r/min
3600
3600
3600
3600
E5-02
Motor Rated Power (for PM Motors)
kW
0.75
1.5
2.2
3.7
E5-03
Motor Rated Current (for PM Motors)
A
4.1
8.0
10.5
16.5
E5-04
Number of Motor Poles (for PM Motors)
–
8
8
8
8
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
0.538
0.20
0.15
0.097
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
3.2
1.3
1.1
1.1
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
3.2
1.3
1.1
1.1
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs
/rad
0
0
0
0
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/
(r/min)
32.4
32.7
36.7
39.7
E1-04
Maximum Output Frequency
Hz
240
240
240
240
E1-05
Maximum Voltage
V
200.0
200.0
200.0
200.0
E1-06
Base Frequency
Hz
240
240
240
240
E1-09
Minimum Output Frequency
Hz
12
12
12
12
A.19 Parameters Changed by Motor Code Selection (for PM Motors)
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
263
A
Parameter List