![YASKAWA Z1000U Series Programming Manual Download Page 183](http://html2.mh-extra.com/html/yaskawa/z1000u-series/z1000u-series_programming-manual_3226538183.webp)
3.
Release the cable from the hooks.
Note:
Models 4
o
0302 to 4
o
0414 have 4 hooks.
A
A –Hook locations
Figure 2.26 Release the Cable
4.
Loosen the 2 screws affixing the cooling fan unit.
Figure 2.27 Remove the Cooling Fan Unit
5.
Unplug the relay connector and release the fan from the drive.
Figure 2.28 Unplug the Relay Connector
u
Installing the Cooling Fan
1.
Pass the cable through the opening of the replacement cooling fan unit from the back side, then plug the relay
connector.
2.5 Drive Cooling Fans
YASKAWA ELECTRIC SIEP C710636 10C Z1000U HVAC MATRIX Drive Programming Manual
183
2
Periodic Inspection & Maintenance