u
Three-Phase 400 V Class Drive Models 4A0124 to 4A0302
Table A.5 Power Ratings Continued (Three-Phase 400 V Class)
Item
Specification
CIMR-Z
o
4A
0124
0156
0180
0240
0302
Maximum
Applicable
Motor
Capacity
Input Voltage
HP
100
125
150
200
250
kW
75
90
110
150
185
Input Voltage
HP
75
100
125
150
220
kW
55
75
90
110
160
Input
Input Current (A)
124
156
180
240
302
Rated Voltage
Rated Frequency
Three-phase 380 to 480 Vac 50/60 Hz / 510 to 680 Vdc
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Minimum Power Supply Capacity (kVA)
104
130
150
200
252
Output
Rated Output Capacity
(kVA)
Input Voltage
460 V or higher
99
124
143
191
241
Input Voltage
lower than 460 V
86
108
125
166
209
Rated Output Current (A)
124
156
180
240
302
Overload Tolerance
110% of rated output current for 60 s
140% of rated output current for 0.5 s
Carrier Frequency
User adjustable between 1 and 10 kHz
(Maximum Frequency varies with Rated Output Capacity)
Maximum Output Voltage (V)
Three-phase 380 to 480 V (proportional to input voltage)
Maximum Output Frequency (Hz)
240 Hz
Harmonics
Reduction
DC Link Choke
Built-in
EMC
Filter (IEC/EN 61800-3 Category 2)
Built-in
connections, and power supply impedance.
<4> Rated motor capacity is calculated with a rated output voltage of 460 V.
<5> Rated motor capacity is calculated with a rated output voltage of 400 V.
<6> Carrier frequency is set to 5 kHz. Current derating is required to raise the carrier frequency.
<7> Carrier frequency is set to 4 kHz. Current derating is required to raise the carrier frequency.
A.1 Power Ratings
272
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
Summary of Contents for Z1000 CIMR-ZU*A Series