Setting
Specification
Characteristic
Application
F
60 Hz
Variable torque
Used for variable torque applications. The default setting is
the same as V/f pattern Setting 7.
to E1-13 are equal to predefined V/f pattern 1.
The following tables show details on predefined V/f patterns.
Predefined V/f Patterns for Models 2A0011 and 4A0005 to 4A0008
The voltage values in the following graphs are specific to 200 V class drives. Double the values for 400 V class drives.
Table 4.26 Constant Torque Characteristics, Settings 0 to 3
Setting = 0
50 Hz
Setting = 1
60 Hz
Setting = 2
60 Hz
Setting = 3
72 Hz
0
10.4
230
1.3 2.5
50
17.3
V
oltage (V)
Frequency (Hz)
0
10.4
17.3
230
1.5 3
60
V
oltage (V)
Frequency (Hz)
0
10.4
17.3
230
1.5 3
60
50
V
oltage (V)
Frequency (Hz)
0
10.4
17.3
230
1.5 3
72
60
V
oltage (V)
Frequency (Hz)
Table 4.27 Variable Torque Characteristics, Settings 4 to 7
Setting = 4
50 Hz
Setting = 5
50 Hz
Setting = 6
60 Hz
Setting = 7
60 Hz
0
9.2
230
1.3
25
50
40.3
V
oltage (V)
Frequency (Hz)
0
10.4
230
1.3
25
50
57.5
V
oltage (V)
Frequency (Hz)
0
9.2
230
1.5
30
60
40.3
V
oltage (V)
Frequency (Hz)
0
10.4
230
1.5
30
60
57.5
V
oltage (V)
Frequency (Hz)
Table 4.28 High Starting Torque, Settings 8 to B
Setting = 8
50 Hz
Setting = 9
50 Hz
Setting = A
60 Hz
Setting = B
60 Hz
0
12.7
230
1.3 2.5
50
21.9
V
oltage (V)
Frequency (Hz)
0
15
230
1.3 2.5
50
27.6
V
oltage (V)
Frequency (Hz)
0
12.7
230
1.5 3
60
21.9
V
oltage (V)
Frequency (Hz)
0
17.3
230
1.5 3
60
27.6
V
oltage (V)
Frequency (Hz)
Table 4.29 Rated Output Operation, Settings C to F
Setting = C
90 Hz
Setting = D
120 Hz
Setting = E
180 Hz
Setting = F
60 Hz
0
10.4
17.3
230
1.5 3
90
60
V
oltage (V)
Frequency (Hz)
0
10.4
17.3
230
1.5 3
120
60
V
oltage (V)
Frequency (Hz)
0
10.4
17.3
230
1.5 3
180
60
V
oltage (V)
Frequency (Hz)
0
10.2
57.5
230
1.5 30
60
V
oltage (V)
Frequency (Hz)
Predefined V/f Patterns for Models 2A0017 to 2A0143 and 4A0011 to 4A0077
The voltage values in the following graphs are specific to 200 V class drives. Double the values for 400 V class drives.