n
T2-03: PM Motor Type
Selects the type of PM motor the drive will operate.
No.
Name
Setting Range
Default
T2-03
PM Motor Type
0, 1
1
Setting 0: IPM motor
Setting 1: SPM motor
n
T2-04: PM Motor Rated Power
Specifies the motor rated power in kilowatts.
No.
Name
Setting Range
Default
T2-04
PM Motor Rated Power
0.00 to 650.00 kW
Determined by o2-04
and C6-01
n
T2-05: PM Motor Rated Voltage
Sets the motor rated voltage.
No.
Name
Setting Range
Default
T2-05
PM Motor Rated Voltage
0.0 to 255.0 V
<1> Value shown is specific to 200 V class drives. Double value for 400 V class drives.
n
T2-06: PM Motor Rated Current
Enter the motor rated current in amps.
No.
Name
Setting Range
Default
T2-06
PM Motor Rated Current
0.0% to 300.0% of the
drive rated current.
Determined by o2-04
n
T2-07: PM Motor Base Frequency
Enter the motor base frequency in Hz.
Note:
T2-07 will be displayed when in OLV/PM.
No.
Name
Setting Range
Default
T2-07
PM Motor Base Frequency
0.0 to 240.0 Hz
87.5 Hz
n
T2-08: Number of PM Motor Poles
Enter the number of motor poles.
No.
Name
Setting Range
Default
T2-08
Number of PM Motor Poles
2 to 48
6
n
T2-10: PM Motor Stator Resistance
Enter the motor stator resistance per motor phase.
No.
Name
Setting Range
Default
T2-10
PM Motor Stator Resistance
0.000 to 65.000 Ω
Determined by T2-02
n
T2-11: PM Motor d-Axis Inductance
Enter the d-Axis inductance per motor phase.
No.
Name
Setting Range
Default
T2-11
PM Motor d-Axis Inductance
0.00 to 600.00 mH
Determined by T2-02
4.8 Auto-Tuning
YASKAWA ELECTRIC TOEP C710616 45F YASKAWA AC Drive – Z1000 User Manual
149
4
Start-Up Programming & Operation
Summary of Contents for Z1000 CIMR-ZU*A Series
Page 399: ......