VS-616PS5 Installation & Quick Start Manual
Page B- 1
APPENDIX B
APPENDIX B
POWERTEC MOTOR SETUP
POWERTEC MOTOR SETUP
B.1
POWERTEC Motors Winding Determination ............................................................................B-1
E and F Series Motors...............................................................................................................B-1
A, B, C, D, and L Series Motors ................................................................................................B-2
Primary feedback Device...........................................................................................................B-2
Secondary Feedback Device.....................................................................................................B-2
B.2
POWERTEC Motors Frame Size and Winding Code Table......................................................B-3
POWERTEC Windings Data .....................................................................................................B-4
B.3
POWERTEC Motors Resolver Information .............................................................................B-13
POWERTEC Industrial Motors of Rock Hill, South Carolina manufactures Brushless DC motors from frac-
tional to 300 HP. These motors are the motors for which the PS5 was originally designed. For information
on the Brushless DC motors, call POWERTEC at 803-328-1888, or fax to 803-328-1870.
B.1
POWERTEC Motors Winding Determination
E and F Series Motors
POWERTEC motor model numbers beginning with “E” or “F” give the motor frame size in the second and third
positions. The stack length is given in the fourth position. Refer to the attached charts of Ferrite motors and PAC-
TORQ (rare earth) motors.
Once the frame size has been determined, the letter in the fifth position of the model number gives the winding let-
ter. Using the frame size and the winding letter, you can obtain the motor winding data to be entered into the “E”
parameters with the “POWERTEC Frame Size and Winding Code Table”. This will give you the four-digit code des-
ignating the winding data.
Enter the four digit number in the E1-02 parameter. If the number is rejected (indicating the number is not in the
drive database), Enter “1000” (CUSTOM) into the E1-02 parameter, and enter the table data into the “E” parame-
ters as shown in the POWERTEC Winding Data Tables.