VS-616PS5 Installation & Quick Start Manual
33
SECTION 5
SECTION 5
PROGRAMMING
PROGRAMMING
5.1 Initializing ...............................................................................................33
Parameter Access..................................................................................33
Operator Status ......................................................................................34
5.2 Quick Start Programming ......................................................................35
Application..............................................................................................35
Tuning ..................................................................................................36
Reference...............................................................................................36
Motor Parameters ..................................................................................38
Automatic Tuning ...................................................................................42
Operation Monitoring..............................................................................44
5.3 Basic Programming ................................................................................46
Note:
Changing parameters while in operation may have drastic consequences.
5.1
Initializing
The inverter parameters are arranged in groups to simplify the task of placing the inverter into service. Almost all of
the parameters have default values that will serve well in the vast majority of applications. This minimizes the num-
ber of parameters that need to be set just to get a motor running.
The parameters are further broken down into access levels. The number of parameters needed to get a motor run-
ning is far fewer than the number of parameters to make a drive work in a system, in a complex application, or to
do complicated actions.
A1 – 01
Parameter Access Level
When power is applied, and the DRIVE/PRGM button is pushed on the operator, parameter A1-01 is the first
parameter to appear. This parameter determines the parameter set available for programming.
Setting
Explanation
Default
0000
Allows access to this parameter and monitor (“U”) parameters only
0001
Accesses special OEM parameters (A2-01 through A2-32)
0002
Quick Start parameters – described in section 5.2
X
0003
Basic Parameters – briefly described in section 5.3
0004
Advanced parameters – described in the VS-616PS5 Programming manual