VS-616PS5 Installation & Quick Start Manual
45
Fault Tracing Parameters
Fault History
Fault Tracing and Fault History are retained when power is lost.
Number
Description
Units
Explanation
U2-01
Existing Fault
- -
Displays a currently existing fault
U2-02
Previous Fault
- -
Displays the last fault detected
U2-03
Speed at time of fault
%
Displays the speed percentage when last fault occurred
U2-04
Frequency at time of fault
Hz
Displays output fundamental frequency at time of last fault
U2-05
Output current at fault
AAC
Displays output current at time of last fault
U2-06
Motor speed at fault
%
Displays the speed at time of last fault
U2-07
Output voltage at fault
VAC
Displays output voltage at time of last fault
U2-08
Bus Voltage at Fault
VDC Displays bus voltage at time of last fault
U2-09
Output Power at fault
KW
Displays output power at time of last fault
U2-10
Torque Reference at fault
%
Displays internal torque reference at time of last fault
U2-11
Input status at time of fault
- -
Displays state of input terminals at time of last fault
U2-12
Output status at time of fault
- -
Displays state of output terminals at time of last fault
U2-13
Drive Status before fault
- -
Displays state of drive internally before last fault occurred
U2-14
Elapsed time since fault
H
Displays elapsed time when last fault was detected
Number
Description
Units
U3-01
Most Recent Fault
- -
U3-02
2
nd
Most Recent Fault
- -
U3-03
3
rd
Most Recent Fault
- -
U3-04
4
th
Most Recent Fault
- -
U3-05
Time since Most Recent Fault
H
U3-06
Time since 2
nd
Most Recent Fault
H
U3-07
Time since 3
rd
Most Recent Fault
H
U3-08
Time since 4
th
Most Recent Fault
H