Installation and Operation Guide SOLECTRIA® PVI 25TL-208, PVI 50TL-480 and PVI 60TL-480
DOCR-071030-A (10/7/2022)
Page 67 of 131
E-total:
KWh
E-Today:
kWh
3 6 9 12 15 18 21 24 h
Running Status Cycle Display
Status Addr:000
2015-10-22 10
:
00:00
Figure 4-3 Default Display Interface for Normal Operation
History
Num
001
002
003
004
005
006
007
008
Time&Date
2015/10/22 12:20:08
2015/10/22 12:30:11
2015/10/22 13:20:08
2015/10/24 10:20:04
2015/10/24 09:31:08
2015/10/25 12:20:08
2015/10/25 16:11:18
2015/10/25 17:21:07
Error Code
W0130
P0020
F0140
F0150
W0130
F0070
P0360
P0050
P1/1
Figure 4-4 Fault Indication Interface
While the inverter is in
Normal Operation
mode (and not in screen saver) the interface indicates PV
voltage, PV current, grid voltage, instant power, daily generated power and time. This is the “Default
Indication Interface.”
(3) Indication of standby mode:
The inverter will enter Standby mode when the output voltage and power of PV modules do not meet the
startup conditions or PV voltage and input power are lower than the set value. The inverter will check
automatically whether it meets the startup conditions in this mode until it turns back to normal mode.
The inverter will switch from standby mode to fault mode if a malfunction occurs.
E-total:
KWh
E-Today:
kWh
6 8 10 12 14 16 18 20 h
Running Status Cycle Display
Standby 485Addr
2015-10-22 05
:
00:00
Figure 4-5 Standby mode
kWh
15
30
45
60
kWh
200
40
80
120
160