Mounting
A mounting bracket, shown in Figure 3-9, is provided with each SOLECTRIA PVI 25TL-208, PVI 50TL-480, and PVI
60TL-480 inverter. The mounting bracket must be securely attached to a structurally sound, flat surface. Acceptable
surfaces include U-channel metal racking (such as Unistrut), concrete, and other non-flammable surfaces.
The total installed weight of the SOLECTRIA PVI 25TL-208, PVI 50TL-480, and PVI 60TL-480 inverter with wiring box
is 156.5 lbs (71 kg). It is the responsibility of the installer to perform a structural analysis of the intended mounting
surface.
NOTICE!
Improper Installation Will Void Warranty
•
Always use the provided mounting bracket secured to a structurally sound surface.
•
Never modify the inverter Power Head or Wiring Box enclosure. Doing so will void the warranty
CAUTION
Improper Installation may result in Property Damage or Personal Injury
•
Never install the inverter directly to drywall unless attached to a structural member.
•
Installing the inverter without the mounting bracket may result in property damage or personal injury.
INFO
✔
Mounting Hardware is Not Included:
The SOLECTRIA PVI 25TL-208, PVI 50TL-480, AND PVI 60TL-480 inverters
are not supplied with fasteners to attach the Mounting Bracket to the substrate. These must be purchased
separately.
Mounting Inverter to Bracket
Locate and mark the 8 holes on the wall, PV racking structure, or weight bearing surface for attaching the inverter
mounting bracket as shown in Figure 3-7.