No.
Name
User
Setting
H1-08
Multi-Function Digital Input Terminal S8 Function
Selection
H2-01
Multi-Function Contact Output (terminal M1-M2)
H2-02
Multi-Function Contact Output 2 (terminal M3-
M4)
H2-03
Multi-Function Contact Output (terminal MD-ME-
MF)
H2-06
Watt Hour Output Unit Selection
H3-01
Terminal A1 Signal Level Selection
H3-02
Terminal A1 Function Selection
H3-03
Terminal A1 Gain Setting
H3-04
Terminal A1 Bias Setting
H3-05
Terminal A3 Signal Level Selection
H3-06
Terminal A3 Function Selection
H3-07
Terminal A3 Gain Setting
H3-08
Terminal A3 Bias Setting
H3-09
Terminal A2 Signal Level Selection
H3-10
Terminal A2 Function Selection
H3-11
Terminal A2 Gain Setting
H3-12
Terminal A2 Bias Setting
H3-13
Analog Input Filter Time Constant
H3-14
Analog Input Terminal Enable Selection
H3-16
Terminal A1 Offset
H3-17
Terminal A2 Offset
H3-18
Terminal A3 Offset
H4-01
Multi-Function Analog Output Terminal FM
Monitor Selection
H4-02
Multi-Function Analog Output Terminal FM Gain
H4-03
Multi-Function Analog Output Terminal FM Bias
H4-04
Multi-Function Analog Output Terminal AM
Monitor Selection
H4-05
Multi-Function Analog Output Terminal AM Gain
H4-06
Multi-Function Analog Output Terminal AM Bias
H4-07
Multi-Function Analog Output Terminal FM
Signal Level Selection
H4-08
Multi-Function Analog Output Terminal AM
Signal Level Selection
H5-01
Drive Node Address
H5-02
Communication Speed Selection
H5-03
Communication Parity Selection
H5-04
Stopping Method After Communication Error (CE)
H5-05
Communication Fault Detection Selection
No.
Name
User
Setting
H5-06
Drive Transmit Wait Time
H5-07
RTS Control Selection
H5-09
CE Detection Time
H5-10
Unit Selection for MEMOBUS/Modbus Register
0025H
H5-11
Communications ENTER Function Selection
H5-12
Run Command Method Selection
H6-01
Pulse Train Input Terminal RP Function Selection
H6-02
Pulse Train Input Scaling
H6-03
Pulse Train Input Gain
H6-04
Pulse Train Input Bias
H6-05
Pulse Train Input Filter Time
H6-08
Pulse Train Input Minimum Frequency
L1-01
Motor Overload Protection Selection
L1-02
Motor Overload Protection Time
L1-03
Motor Overheat Alarm Operation Selection (PTC
input)
L1-04
Motor Overheat Fault Operation Selection (PTC
input)
L1-05
Motor Temperature Input Filter Time (PTC input)
L1-13
Continuous Electrothermal Operation Selection
L1-15
Motor 1 Thermistor Selection (NTC)
L1-16
Motor 1 Overheat Temperature
L1-20
Operation at Motor Overheat (oH5)
L2-01
Momentary Power Loss Operation Selection
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Ramp
Time
L2-05
Undervoltage Detection Level (Uv1)
L2-06
KEB Deceleration Time
L2-07
KEB Acceleration Time
L2-08
Frequency Gain at KEB Start
L2-10
KEB Detection Time (Minimum KEB Time)
L2-11
DC Bus Voltage Setpoint during KEB
L2-29
KEB Method Selection
L3-01
Stall Prevention Selection during Acceleration
L3-02
Stall Prevention Level during Acceleration
L3-03
Stall Prevention Limit during Acceleration
Stall Prevention Selection during Deceleration
L3-05
Stall Prevention Selection during Run
L3-06
Stall Prevention Level during Run
L3-11
Overvoltage Suppression Function Selection
L3-17
Target DC Bus Voltage for Overvoltage
Suppression and Stall Prevention
L3-20
DC Bus Voltage Adjustment Gain
L3-21
Accel/Decel Rate Calculation Gain
E.3 User Setting Table
576