12.6 H: Terminal Function Selection
320
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
■
51: Output Contactor Control
Setting Value
Function
Description
51
Output Contactor Control
Assigning this command to an output terminal can send a signal to the controller to close the output contactor. The output
contactor should open when the terminal is released.
Closed : Close output contactor
■
54: Light Load Direction
Setting Value
Function
Description
54
Light Load Direction
Indicates the light load direction detected during emergency operation with light load search. When the terminal is closed the
light load direction is up, when it is open the light load direction is down.
Closed : Light load direction is up
Open : Light load direction is down
■
58: Safe Disable Status
Setting Value
Function
Description
58
Safe Disable Status
This terminal closes if the Safe Disable inputs H1-HC are closed and opens when terminals H1-HC are open.
Closed : Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open : Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
■
100 to 158: Inverse output of 0 to 58
Setting Value
Function
Description
100 - 158
Inverse output of 0 to 58
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which function to
inversely output.
For example, set
H2-xx = 10E
for the inverse output of
E [Fault]
.
◆
H4: Analog Outputs
H4 parameters
set the drive analog monitors. These parameters select monitor parameters, adjust gain and bias,
and select output signal levels.
■
Calibrate Meters Connected to MFAO Terminal AM
Use these parameters to calibrate meters connected to terminal AM:
•
H4-02 [Terminal AM Analog Output Gain]
•
H4-03 [Terminal AM Analog Output Bias]
Set these parameters where the output voltage of 10 V are 100% of the signal level.
No.
Name
Range
Default
H4-02
Terminal AM Analog Output Gain
-999.9 - +999.9%
100.0%
H4-03
Terminal AM Analog Output Bias
-999.9 - +999.9%
0.0%
and
show the gain and bias.
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
Summary of Contents for LA500
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...