No.
(Hex.)
Name
Description
Default
(Range)
Ref.
E2-09
(0316)
Expert
Motor Mechanical Loss
Sets the mechanical loss of the motor. It is set as a percentage of
E2-11 [Motor Rated
Power]
. Usually it is not necessary to change this setting.
0.0%
(0.0 - 10.0%)
E2-10
(0317)
Motor Iron Loss
Sets the motor iron loss.
Determined by o2-04
(0 - 65535 W)
E2-11
(0318)
Motor Rated Power
Sets the motor rated output in the units from
o1-58 [Motor Power Unit Selection]
.
Determined by o2-04
(0.00 - 650.00 kW)