7.10 Troubleshooting Without Fault Display
198
YASKAWA
SIEPYEULA5001C LA500 Technical Manual
Causes
Possible Solutions
You pushed
.
Turn the Run command OFF then ON from an external input.
Note:
When you push
during operation, the drive will ramp to stop. Set
o2-02 = 0 [STOP
Key Function Selection = Disabled]
to disable the
function.
The 2-wire sequence and 3-wire sequence are not set correctly.
•
Set one of the parameters
H1-03 to H1-07 [Terminals S3 to S7 Function Select]
to
0 [3-Wire
Sequence]
to enable the 3-wire sequence.
•
If a 2-wire sequence is necessary, make sure that
H1-03 to H1-07 ≠ 0
.
◆
The Motor Rotates in the Opposite Direction from the Up/Down Command
Causes
Possible Solutions
The phase wiring between the drive and motor is incorrect.
•
Examine the wiring between the drive and motor.
•
Connect drive output terminals U/T1, V/T2, and W/T3 in the correct sequence to agree with
motor terminals U, V, and W.
•
Switch two motor cables U, V, and W to reverse motor direction.
Drive control circuit terminals for the Up and Down commands are
switched.
•
Connect drive output terminals U/T1, V/T2, and W/T3 in the correct sequence to agree with
motor terminals U, V, and W.
•
Switch two motor cables U, V, and W to reverse motor direction.
Figure 7.1 Forward Rotating Motor
Note:
•
For Yaskawa motors, the forward direction is counterclockwise when looking from the
motor shaft side.
•
Refer to the motor specifications, and make sure that the forward rotation direction is
correct for the application. The forward rotation direction of motors can be different for
different motor manufacturers and types.
The signal connections for forward run and reverse run on the drive control
circuit terminals and control panel side are incorrect.
Correctly wire the control circuit.
◆
The Motor Rotates in Only One Direction
Causes
Possible Solutions
The drive will not let the motor rotate in reverse.
Set
b1-04 = 0 [Reverse Operation Selection = Reverse Enabled]
.
The drive did not receive a Reverse run signal and 3-Wire sequence is
selected.
Activate the terminals to which
H1-xx = 0 [3-Wire Sequence]
is set, and then enable reverse
operation.
◆
The Motor Is Too Hot
Causes
Possible Solutions
The load is too heavy.
•
Decrease the load.
•
Increase the acceleration and deceleration times.
•
Examine the values set in
L1-01 [Motor Overload (oL1) Protection]
,
L1-02 [Motor Overload
Protection Time]
, and
E2-01 [Motor Rated Current (FLA)]
.
•
Use a larger motor.
Note:
The motor also has a short-term overload rating. Examine this rating carefully before setting
drive parameters.
The motor is running continuously at a very low speed.
•
Change the run speed.
•
Use a drive-dedicated motor.
The drive is operating in a vector control mode, but Auto-Tuning has not
been done.
•
Do Auto-Tuning.
•
Calculate motor parameter and set motor parameters.
•
Set
A1-02 = 0 [Control Method Selection = V/f Control]
.
The voltage insulation between motor phases is not sufficient.
•
Use a motor with a voltage tolerance that is higher than the maximum voltage surge.
•
Use a drive-dedicated motor that is rated for use with AC drives for applications that use a
motor on drives rated higher than 400 V class.
•
Install an AC reactor on the output side of the drive and set
C6-02 = 1 [Carrier Frequency
Selection = 2.0 kHz]
.
Note:
When the motor is connected to the drive output terminals U/T1, V/T2, and W/T3, surges
occur between the drive switching and the motor coils. These surges can be three times the
drive input power supply voltage (600 V for a 200 V class drive, 1200 V for a 400 V class
drive).
Summary of Contents for LA500
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 10: ...10 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 18: ...i 3 Glossary 18 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 74: ...3 14 Wiring Checklist 74 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 164: ...6 1 MEMOBUS Modbus Communications 164 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 202: ...7 10 Troubleshooting Without Fault Display 202 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 218: ...8 6 Storage Guidelines 218 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 234: ...10 6 Peripheral Devices and Options 234 YASKAWA SIEPYEULA5001C LA500 Technical Manual...
Page 375: ...YASKAWA SIEPYEULA5001C LA500 Technical Manual 375...