The following table provides a list of SVB and SVR motion fixed parameters.
Slot
Number
Name
Contents
SVB SVR
0
Selection of Operation Modes
0: Normal Operation Mode
Yes
Yes
1: Axis Unused
Yes
Yes
2: Simulation Mode
Yes
3: Servo Driver Transmission Reference Mode
Yes
4 and 5: Reserved
−
−
1
Function Selection Flag 1
Bit 0: Axis Selection (0: Finite length axis/1: Infinite length axis)
• Set to 0 for linear type.
Yes
Yes
Bit 1: Soft Limit (Positive Direction) Enable/Disable
Yes
Bit 2: Soft Limit (Negative Direction) Enable/Disable
Yes
Bit 3: Overtravel Positive Direction Enable/Disable
Yes
Bit 4: Overtravel Negative Direction Enable/Disable
Yes
Bits 5 to 7: Reserved
−
−
Bit 8: Interpolation Segment Distribution Processing
Yes
Bit 9: Simple ABS Rotary Pos. Mode (Simple Absolute Infinite Axis Position
Control) (0: Disabled/1: Enabled)
• Set to 0 for linear type.
Yes
Bit A: User Constants Self-writing Function
Yes
Bits B to F: Reserved
2
Function Selection Flag 2
Bit 0: Communication Abnormality Detection Mask
Yes
Bit 1: WDT Abnormality Detection Mask
Yes
Bits 2 to F: Reserved for system use.
−
−
3
−
Reserved
−
−
4
Reference Unit Selection
0: pulse, 1: mm, 2: deg, 3: inch, 4:
μ
m
• For linear type, only valid for 0: pulse, 1: mm, 4:
μ
m.
When 2: deg, 3: inch is set, converted into 1: mm.
Yes
Yes
5
Number of Digits below Decimal
Places
1 = 1 digit
Yes
Yes
6
Travel Distance per Machine
Rotation
(Rotary Motor)
1 = 1 reference unit
Yes
Yes
Linear Scale Pitch
(Linear Type)
1 = 1 reference unit
Yes
Yes
8
Servo Motor Gear Ratio
1 = 1 rotation (This setting is ignored if a linear motor is selected.)
Yes
Yes
9
Machine Gear Ratio
1 = 1 rotation (This setting is ignored if a linear motor is selected.)
Yes
Yes
10
Infinite Length Axis Reset
Position (POSMAX)
1 = 1 reference units
• Invalid for linear type.
Yes
Yes
12
Positive Software Limit Value
1 = 1 reference unit
Yes
14
Negative Software Limit Value
1 = 1 reference unit
Yes
16
Backlash Compensation
Amount
1 = 1 reference unit
Yes
18 to 29
−
Reserved
−
−
30
Encoder Selection
0: Incremental Encoder
1: Absolute Encoder
2: Absolute Encoder (Incremental encoder is used.)
3: Reserved
Yes
31 to 33
−
Reserved
−
−
Summary of Contents for JEPMC-MP2300S-E
Page 14: ...MEMO ...
Page 24: ...MEMO ...
Page 114: ...MEMO ...
Page 132: ...MEMO ...
Page 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Page 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Page 190: ...MEMO ...
Page 280: ...MEMO ...
Page 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Page 310: ...MEMO ...