![YASKAWA JEPMC-MP2300S-E User Manual Download Page 195](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300s-e/jepmc-mp2300s-e_user-manual_907071195.webp)
6.2 Communication with Other MP Series
6.2.1 When the MP2300S Acts as Slave (automatic receive function is used)
6-5
6
Ethernet Communications
( 1 ) How to Set up the MP2300S Side
If the setting of transmission parameters (IP address, subnet mask) is already completed, start from step 3.
1.
Double-click the
218IFA
Tab in the
Module Details
Window of the module configuration definition.
2.
Set transmission parameters.
How to set up transmission parameters
Set
IP Address
(to “192.168.001.001,” for example).
Set
Subnet Mask
(to “255.255.255.000,” for example).
Set
Gateway IP Address
(to “000.000.000.000,” for example).
Caution
Set up a unique IP address in the network.
For the IP address, check with your network administrator.
3.
Click the
Easy Setting
Button in the
Message Communication
area of the connection parameter set-
ting.