4.5 Starting Motion Program from an External Signal
4.5.3 Creation Procedure
4-16
2.
Registering Program Execution
• A
Program Execution Registry Screen
Dialog Box will appear.
• Click the
List
Button to set a program definition in the
M-EXECUTOR
Window.
→
Then register the MPM001, SPM001 executions.
For more information on how to set the
M-EXECUTOR
Window, refer to
2.2.7 M-EXECUTOR Module
(Motion Program Executor)
on page 2-50.
• In the
Allocation Control Register
Window, map the M registers allocated to control signals (
Start
/
Stop
/
Alarm Clear
) and status (
Running Program
/
Alarm
) on the touch panel as an M-EXECU-
TOR allocation register for the motion program created in
4.3 Programming (step 2)
.
Status=MW00501, control signal=MW00500, allocation contact interlock =SB00004