No.
Description
Unit
Setting Range
−
Model
−
4V0011
4V0018
4V0023
4V0031
4V0038
o2-04
Drive Model Selection
−
97
99
9A
9C
9D
E2-11
Motor Rated Power
kW
5.5
7.5
11.0
15.0
18.5
b3-06
Speed Search current 1
−
0.5
0.5
0.5
0.5
0.5
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
–
0.5
0.5
0.5
0.5
0.5
C6-02
Carrier frequency
−
7
7
7
7
7
E2-01
Motor rated current
A
9.8
13.30
19.9
26.5
32.9
E2-02
Motor rated slip
Hz
1.5
1.3
1.70
1.60
1.67
E2-03
Motor no-load current
A
2.6
4.0
5.6
7.6
7.8
E2-05
Motor line-to-line resistance
Ω
1.595
1.152
0.922
0.550
0.403
E2-06
Motor leakage inductance
%
18.2
15.5
19.6
17.2
20.1
E2-10
Motor Iron Loss
W
193
263
385
440
508
L2-02
Momentary power loss ride-through time
s
0.5
0.8
1
2
2
L2-03
Momentary power loss Baseblock time
s
0.7
0.8
0.9
1.0
1.0
L2-04
Momentary power loss voltage recovery time
s
0.3
0.3
0.3
0.6
0.6
L2-05
Uv detection voltage
V dc
380
380
380
380
380
L3-24
Motor acceleration time
s
0.154
0.175
0.265
0.244
0.317
L8-02
Overheat alarm level
°C
100
110
110
110
110
L8-09
Ground fault selection
−
0
1
1
1
1
L8-38
Carrier frequency reduction selection
−
1
2
2
2
2
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
10