u
Three-Phase 200 V Class Drives
Table A.2 Three-Phase 200 V Class Power Ratings
Item
Specification
Three-Phase Drive Model
2V0006
2V0010
2V0012
2V0020
Maximum Motor Size Allowed kW (HP)
1.1 (1.5)
2.2 (3)
3.0 (3)
5.5 (5)
Input
Input Current (A)
7.3
10.8
13.9
24.0
Output
Rated Output Capacity (kVA)
2.3
3.7
4.6
7.5
Output Current (A)
6.0
9.6
12.0
19.6
Overload Tolerance
120% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable 2 to 15 kHz
Max Output Voltage (V)
Three-phase power: 200 to 240 V
(proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power Supply
Rated Voltage
Rated Frequency
Three-phase power: 200 to 240 V 50/60 Hz
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency
Fluctuation
±5%
Harmonic Corrective
Actions
DC Link Choke
Optional
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.
Table A.3 Three-Phase 200 V Class Power Ratings Continued
Item
Specification
Three-Phase Model
2V0030
2V0040
2V0056
2V0069
Maximum Motor Size Allowed kW (HP)
7.5 (10)
11 (10)
15 (20)
18.5 (25)
Input
Input Current (A)
37.0
52.0
68.0
80.0
Output
Rated Output Capacity (kVA)
11.4
15.2
21.3
26.3
Output Current (A)
30.0
40.0
56.0
69.0
Overload Tolerance
120% of rated output current for 1 minute
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable 2 to 15 kHz
Max Output Voltage (V)
Three-phase power: 200 to 240 V
(proportional to input voltage)
Max Output Frequency (Hz)
400 Hz (user-adjustable)
Power Supply
Rated Voltage
Rated Frequency
Three-phase power: 200 to 240 V 50/60 Hz
DC power supply: 270 to 340 V
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency
Fluctuation
±5%
Harmonic Corrective
Actions
DC Link Choke
Optional
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 230 V.
<4> DC is not available for UL standards.
A.1 Power Ratings