APPLICATIONS OF
Σ
-SERIES PRODUCTS
3.2.12
Using the Analog Monitor
102
3.2.12 Using the Analog Monitor
1) The following two analog voltage monitor signals are output.
Output
→
TRQ-M 1CN-16
Torque monitor
For Speed/Torque
Control
Output
→
VTG-M 1CN-17
Speed monitor
Control
TRQ-M : Torque monitor output (
¦
3V/
¦
100% torque)
VTG-M : Speed monitor output (
¦
3V/
¦
1000 r/min)
•
As for the check terminals of the front panel:
TMON is the same signal as TRQ-M
VTG is the same signal as VTG-M
Signal ground for TMON and VTG is SG0V of check terminals.
The following memory switch is used to modify the signal specifications.
Cn-02
Bit 6
TRQ-M Specifications
Factory
Setting: 0
For Speed/Torque Control
Setting
Meaning
0
Uses TRQ-M as the torque reference monitor output.
1
Uses TRQ-M as the speed reference monitor output.
3