SERVO SELECTION AND DATA SHEETS
5.3.1
Ratings and Specifications
cont.
234
Voltage
200 VAC
100 VAC
Servopack Type
DR2- A3AC
A5AC
01AC
02AC
04AC
08AC
A3BC
A5BC
01BC
02BC
03BC
Max. Applicable Motor Capacity
W (HP)
30
(0.04)
50
(0.07)
100
(0.13)
200
(0.27)
400
(0.53)
750
(1.01)
30
(0.04)
50
(0.07)
100
(0.13)
200
(0.27)
300
(0.40)
Basic
Specifica-
ti
Power Supply
(Main/control circuit)
Single-phase 200 to 230 VAC+10% to
−
15%,
50/60Hz
Single-phase 100 to 115 VAC+10% to
−
15%*
2
, 50/60Hz
p
tions
Control Method
Single-phase, full-wave rectification IGBT-PWM (sine-wave driven)
Feedback
Incremental encoder 2048 P/R, absolute encoder 1024 P/R
Loca-
i
Ambient Temp.
0 to +55
°
C*
3
tion
Storage Temp.
−
20 to +85
°
C
Ambient/Stor-
age Humidity
90% or less (non-condensing)
Vibration/Shock
Resistance
0.5/2G
Structure
Rack-mounted*
7
Approx. Mass
kg (lb)
2.5 (5.51)
3.7 (8.16)
2.5 (5.51)
3.7 (8.16)
Perfor-
Speed Control Range*
4
1:5000
mance
Speed
Regu-
l ti *
5
Load
Regulation
0% to 100%:0.01% max. (at rated speed)
g
lation*
5
Voltage
Regulation
+10% to -15%: 0.01% max. (at rated speed)
Temperature
Regulation
25
¦
25
°
C:
¦
0.2% max. (at rated speed)
Frequency
Characteristics
250 Hz (at J
L
=J
M
)
Torque Control
(Repeatability)
¦
2.0%
Accel/Decel Time Setting
0 to 10 s
Input
Signal
Speed
Refer-
ence
Rated Refer-
ence Voltage
¦
6 VDC (positive motor rotation with positive reference) at rated speed (factory setting)
Variable setting range:
¦
2 to
¦
10 VDC at rated torque
ence
Input
Impedance
Approx. 30k
Ω
Circuit Time
Constant
Approx. 330
µ
s
Torque
Refer-
ence
Rated Refer-
ence Voltage
¦
3 VDC (positive motor rotation with positive reference) at rated speed (factory setting)
Variable setting range:
¦
1 to
¦
10 VDC at rated torque
ence
Input
Impedance
Approx. 30k
Ω
Circuit Time
Constant
Approx. 330
µ
s
I/O
Si
l
Posi-
i
Output Form
A-, B-, C-phase line driver*
8
/
Signals
tion
Output
Frequency
Dividing Ratio
(16 to N) /N (N=2048, 1024)*
6
Sequence Input
Servo ON, P drive (or motor forward/reverse by torque control, zero-clamp drive reference, or
internal setting speed), forward run stop (P-OT), reverse run stop (N-OT), current limit + selection
(or internal speed selection), current limit
−
selection (or internal speed selection), alarm reset
Sequence Output
Torque limit detection (or speed coincidence) , motor running output (or external brake interlock),
servo ready, servo alarm, 3-bit alarm codes
Dynamic Brake
Operated at main power OFF, servo alarm or overtravel.
External Regenerative Unit
Required when exceeding the allowable load inertia*
1
Overtravel
Dynamic brake stop at P-OT or N-OT or deceleration stop
Protective Functions
Overcurrent, overload, overvoltage, overspeed, reference input read error, overrun prevention,
origin error, CPU error, encoder error, fuse blown
5