LIST OF USER CONSTANTS
472
Category
Remarks
Factory
Setting
Upper
Limit
Lower
Limit
Unit
Name
Code
User
Constant
No.
Sequence
Related
Constants
Cn-16
BRKWAI
Output timing
of brake
reference
during motor
operation
10 ms
10
100
50
See 3.4.4.
Cn-1B
COINLV
Positioning
complete range
Reference
unit
0
250
7
See 3.7.3.
Pulse
Related
Constants
Cn-0A
PGRAT
Dividing ratio
setting
P/R
16
32768
2048
See note 1
See 3.2.3.
Cn-11
PULSNO
Number of
encoder pulses
P/R
513
32768
2048
See note 1
See 3.3.3,
3.8.5.
Cn-24
RATB
Electronic gear
ratio
(numerator)
4
65535
4
See note 3
See 3.2.3,
3.2.5.
Cn-25
RATA
Electronic gear
ratio
(denominator)
1
65535
1
See note 3
See 3.2.3,
3.2.5.
Cn-2A
PULSNO2
External PG
number of
pulses
P/R
513
32768
2048
Other
Constants
Cn-0C
TRQMSW
Mode switch
(torque
reference)
%
0
Max.
torque
200
See 3.6.6.
Cn-0D
REFMSW
Mode switch
(speed
reference)
r/min
0
4500
0
See 3.6.6.
Cn-0E
ACCMSW
Mode switch
(acceleration
reference)
10 (r/min)/s 0
3000
0
See 3.6.6.
Cn-0F
ERPMSW
Mode switch
(error pulse)
Reference
unit
0
10000
0
See 3.6.6.
Cn-10
JOGSPD
Jog speed
r/min
0
4500
500
See 3.3.2.
Cn-1E
OVERLV
Overflow
×
256
reference
unit
1
32767
1024
See note 4
See 3.5.2,
3.6.2.
Cn-1F
SPEED1
1st speed
(contact input
speed control)
r/min
0
4500
100
See 3.2.6.
Cn-20
SPEED2
2nd speed
(contact input
speed control)
r/min
0
4500
200
See 3.2.6.
Cn-21
SPEED3
3rd speed
(contact input
speed control)
r/min
0
4500
300
See 3.2.6.
Cn-28
NFBCC
Speed loop
compensation
constant
---
0
100
0
: User constants that must be always set