LIST OF ALARM DISPLAYS
478
Alarm Display
Alarm Display
Di i l
7-
Alarm Output
Alarm Name
Meaning
Remarks
p y
on Digital
Operator
segment
LED
Alarm Code Output
ALM
O
g
Operator
LED
ALO1
AL02
AL03
Output
OFF
OFF
OFF
OFF
Absolute data
error
Absolute data fails to be
received, or received
absolute data is
abnormal.
For
absolute
encoder
only
OFF
OFF
OFF
OFF
User constant
breakdown
Checksum
results of
user constants are
abnormal.
OFF
OFF
OFF
OFF
User constant
setting error
The user constant
setting is outside the
allowable setting range.
ON
OFF
OFF
OFF
Overcurrent
An overcurrent flowed
through the power
transistor.
OFF
ON
OFF
OFF
Blown fuse
Fuse is blown.
ON
ON
OFF
OFF
Regenerative
error
Defective regenerative
resistor
Regenerative resistor
disconnection
ON
ON
OFF
OFF
Position error
pulse overflow
Position error pulse has
exceeded the value set
in user constant Cn-1E
(overflow).
For
position
control
only
OFF
OFF
ON
OFF
Overvoltage or
undervoltage
The main circuit voltage
for motor operation has
become too high or too
low.
ON
OFF
ON
OFF
Overspeed
Motor speed has
exceeded 4950 r/min.
ON
ON
ON
OFF
Overload
Rated torque was
exceeded during
continuous operation.
OFF
OFF
OFF
OFF
Absolute
encoder error
The number of pulses
per absolute encoder
revolution is abnormal.
For
absolute
encoder
only
OFF:
Output transistor is OFF
ON
:
Output transistor is ON
TERMS
Checksum
An automatic check function for a set of data such as user constants. It stores the sum of
user constant data, recalculates the sum at specific timing, and then checks whether the
stored value matches the recalculated value. This function is a simple method of checking
whether a set of data is correct.
E