model no.
060-0608-2
| contact us: 1.866.523.5218
50
MAINT
eNANC
e
2. Slide rubber boot back, loosen the nut
(A) counterclockwise, then loosen the
center bolt (B) clockwise. Test function.
Tighten the nut clockwise against the
long sleeve bolt. Slide rubber boot
back to cover the nut. Lengthening this
nut connection will create more tension
with the auger belt. Do not over adjust
the cable, too much tension on belt will
not allow the belt to separate from the
pulley when disengaging. If the belt
isn’t allowed to disengage properly,
you could cause premature wearing
of the belt and ultimately cause belt
failure. (Fig. 43)
A
b
Figure 43
3. With a helper, operate the auger control on and off with the control lever, and make
sure the auger visually isn’t turning when released (Your helper would need to be a
safe distance to help you determine if the adjustments are working. They will need to
view the auger or impeller rotation while you press down or release the control lever). If
when released, there is a slightly turning of the auger, make slight adjustments to fine
tune performance to stop the rotation when released, but working when pressed down.